| Assessment Year | 2025 |
|---|---|
| Principal Product | Signs |
| NAICS | 339950: Sign Manufacturing |
| SIC | 3993: Signs and Advertising Specialties |
| Sales Range | $50 M to 100M |
| # of Employees | 50 |
| Plant Area |
72,000
ft2
|
| Annual Production | 5,000
units
|
| Production Hrs. Annual | 3,276
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $165,218 | 1,420,302 |
kWh
|
$0.12 |
| Electricity Fees | $504 | - |
|
- |
| Natural Gas | $47,587 | 4,222 |
MMBtu
|
$11.27 |
| TOTAL YEARLY COSTS | $213,309 | |||
| RECOMMENDED SAVINGS* | $89,535 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,083 | $8,883 |
$7,447
64,201
kWh
|
$(-1,364.0)
-
MMBtu
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $912 | $420 |
$912
7,862
kWh
|
- | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $1,748 | - |
$1,748
15,070
kWh
|
- | |
| 04 | 2.2511: Insulate bare equipment | $38,059 | $9,385 |
$38,059
328,096
kWh
|
- | |
| 05 | 2.9114: Use solar heat to make electricty | $33,575 | $187,740 |
$33,575
289,440
kWh
|
- | |
| 06 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $9,158 | $8,500 | - |
$9,158
-
MMBtu
|
|
| TOTAL RECOMMENDED | $89,535 | $214,928 |
$81,741
704,669
kWh
|
$7,794
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs