Assessment Year | 2025 |
---|---|
Principal Product | Signs |
NAICS | 339950: Sign Manufacturing |
SIC | 3993: Signs and Advertising Specialties |
Sales Range | $50 M to 100M |
# of Employees | 50 |
Plant Area |
72,000
ft2
|
Annual Production | 5,000
units
|
Production Hrs. Annual | 3,276
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $165,218 | 1,420,302 |
kWh
|
$0.12 |
Natural Gas | $47,587 | 4,222 |
MMBtu
|
$11.27 |
TOTAL YEARLY COSTS | $212,805 | |||
RECOMMENDED SAVINGS* | $89,535 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,083 | $8,883 |
$7,447
64,201
kWh
|
$(-1,364.0)
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $912 | $420 |
$912
7,862
kWh
|
- | |
03 | 2.7124: Make a practice of turning off lights when not needed | $1,748 | - |
$1,748
15,070
kWh
|
- | |
04 | 2.2511: Insulate bare equipment | $38,059 | $9,385 |
$38,059
328,096
kWh
|
- | |
05 | 2.9114: Use solar heat to make electricty | $33,575 | $187,740 |
$33,575
289,440
kWh
|
- | |
06 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $9,158 | $8,500 | - |
$9,158
-
MMBtu
|
|
TOTAL RECOMMENDED | $89,535 | $214,928 |
$81,741
704,669
kWh
|
$7,794
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs