| Assessment Year | 2023 |
|---|---|
| Principal Product | Architectural Flat Glass |
| NAICS | 327211: Flat Glass Manufacturing |
| SIC | 3211: Flat Glass |
| Sales Range | $100 M to 500M |
| # of Employees | 320 |
| Plant Area |
1,090,000
ft2
|
| Annual Production | 264,000
ton
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $4,796,664 | 78,765,890 |
kWh
|
$0.061 |
| Natural Gas | $23,172,383 | 3,247,451 |
MMBtu
|
$7.14 |
| TOTAL YEARLY COSTS | $27,969,047 | |||
| RECOMMENDED SAVINGS* | $405,825 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $18,128 | $20,072 |
$18,128
297,183
kWh
|
|
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $19,139 | $26,000 |
$19,139
313,746
kWh
|
|
| 03 | 2.9114: Use solar heat to make electricty | $368,558 | $2,575,793 |
$368,558
6,041,933
kWh
|
|
| TOTAL RECOMMENDED | $405,825 | $2,621,865 |
$405,825
6,652,862
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs