Assessment Year 2023
Principal Product Automotive Substrates for Catalytic Converters
NAICS 336390: Other Motor Vehicle Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $100
M
to 500
M
# of Employees 250
Plant Area 474,000
ft2
Annual Production 80,000,000
units
Production Hrs. Annual 8,760
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,478,712 42,787,588
kWh
Natural Gas $3,077,908 407,132
MMBtu
TOTAL YEARLY COSTS $5,556,620
RECOMMENDED SAVINGS* $145,712 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.9114: Use solar heat to make electricty $134,987 $998,777 $134,987
2,327,354
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,490 $1,719 $2,490
42,924
kWh
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $8,235 $14,800 $8,235
141,983
kWh
TOTAL RECOMMENDED $145,712 $1,015,296 $145,712
2,512,261
kWh
TOTAL IMPLEMENTED - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs