Assessment Year | 2023 |
---|---|
Principal Product | Hydraulic Pumps |
NAICS | 333996: Fluid Power Pump and Motor Manufacturing |
SIC | 3594: Fluid Power Pumps and Motors |
Sales Range | $100 M to 500M |
# of Employees | 300 |
Plant Area |
190,000
ft2
|
Annual Production | 72,000
units
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $743,665 | 8,771,200 |
kWh
|
$0.085 |
Electricity Demand | $159,254 | 21,047 |
kW-mo/yr
|
$7.57 |
Electricity Fees | $2,691 | - |
|
- |
Natural Gas | $18,249 | 1,540 |
MMBtu
|
$11.85 |
TOTAL YEARLY COSTS | $923,859 | |||
RECOMMENDED SAVINGS* | $215,599 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2612: Use cooling tower water instead of refrigeration | $55,102 | $47,144 |
$50,553
594,737
kWh
|
$4,549
-
kW-mo/yr
|
|
02 | 2.7241: Install outside air damper / economizer on hvac unit | $12,633 | $40,000 |
$11,331
133,300
kWh
|
$1,302
-
kW-mo/yr
|
|
03 | 2.9114: Use solar heat to make electricty | $147,864 | $750,960 |
$147,864
1,739,576
kWh
|
- | |
TOTAL RECOMMENDED | $215,599 | $838,104 |
$209,748
2,467,613
kWh
|
$5,851
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs