ITAC Assessment: CC0018
ITAC logo
ITAC Assessment: CC0018
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Bubble Wrap, Instapak Film, Jiffylite
NAICS 326112: Plastics Packaging Film and Sheet (including Laminated) Manufacturing
SIC 2671: Packaging Paper and Plastics Film, Coated and Laminated
Sales Range $50
M
to 100
M
# of Employees 140
Plant Area 164,000
ft2
Annual Production 26,455,471
lb
Production Hrs. Annual 8,760
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $503,452 13,392,237
kWh
Electricity Demand $287,019 26,129
kW-mo/yr
Electricity Fees $10,854 -
Fuel Oil #2 $240,165 8,248
MMBtu
TOTAL YEARLY COSTS $1,041,490
RECOMMENDED SAVINGS* $153,005 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Fuel Oil #2 Savings
01 2.2123: Insulate feedwater tank $2,497 $500 - - $2,497
-
MMBtu
02 2.2437: Recover waste heat from equipment $31,506 $10,000 $(-994.0)
(-26,162)
kWh
$(-491.0)
-
kW-mo/yr
$32,991
-
MMBtu
03 2.4239: Eliminate or reduce compressed air usage $5,158 $10,000 $3,695
97,236
kWh
$1,463
-
kW-mo/yr
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $2,300 - $1,648
43,362
kWh
$652
-
kW-mo/yr
-
05 2.2612: Use cooling tower water instead of refrigeration $16,265 $70,000 $16,265
428,025
kWh
- -
06 2.1321: Replace fossil fuel equipment with electrical equipment $95,279 $350,000 $(-73,483.9)
(-1,933,787)
kWh
$(-71,402.5)
-
kW-mo/yr
$240,165
-
MMBtu
TOTAL RECOMMENDED $153,005 $440,500 $(-52,869.9)
(-1,391,326)
kWh
$(-69,778.5)
-
kW-mo/yr
$275,653
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Fuel Oil #2 Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs