ITAC Assessment: CC0001
ITAC logo
ITAC Assessment: CC0001
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product surface mounted door closers and electro-mechanical door closers (operators)
NAICS 335999: All Other Miscellaneous Electrical Equipment and Component Manufacturing
SIC 3699: Electrical Machinery, Equipment, and Supplies, Not Elsewhere
Sales Range $100
M
to 500
M
# of Employees 198
Plant Area 132,400
ft2
Annual Production 1,475,269
units
Production Hrs. Annual 6,240
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $471,820 7,643,684
kWh
Electricity Fees $1,059 -
Natural Gas $108,397 11,388
MMBtu
TOTAL YEARLY COSTS $581,276
RECOMMENDED SAVINGS* $82,475 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2437: Recover waste heat from equipment $42,438 $42,308 $(-802.0)
(-12,931)
kWh
$43,240
-
MMBtu
02 2.6218: Turn off equipment when not in use $3,092 - $3,092
49,875
kWh
-
03 2.7224: Reduce space conditioning during non-working hours $26,528 - $26,528
427,867
kWh
-
04 2.7226: Use computer programs to optimize hvac performance $9,732 $10,000 $9,732
156,960
kWh
-
05 2.7224: Reduce space conditioning during non-working hours $601 - $601
9,700
kWh
-
06 2.6211: Conserve energy by efficient use of vending machines $84 $180 $84
1,361
kWh
-
TOTAL RECOMMENDED $82,475 $52,488 $39,235
632,832
kWh
$43,240
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs