| Assessment Year | 2021 |
|---|---|
| Principal Product | Excavator equipment |
| NAICS | 333120: Construction Machinery Manufacturing |
| SIC | 3531: Construction Machinery and Equipment |
| Sales Range | $1 M to 5M |
| # of Employees | 18 |
| Plant Area |
401,314
ft2
|
| Annual Production | 275
units
|
| Production Hrs. Annual | 2,184
hrs
|
| Location (State) | Montana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $8,823 | 138,520 |
kWh
|
$0.064 |
| Electricity Fees | $10,150 | - |
|
- |
| Natural Gas | $2,075 | 674 |
MMBtu
|
$3.08 |
| TOTAL YEARLY COSTS | $21,048 | |||
| RECOMMENDED SAVINGS* | $2,653 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $937 | $22 |
$937
14,633
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $629 | $375 |
$629
9,828
kWh
|
|
| 03 | 2.7135: Install occupancy sensors | $151 | $180 |
$151
2,359
kWh
|
|
| 04 | 2.7145: Install skylights | $254 | $2,020 |
$254
3,968
kWh
|
|
| 05 | 2.7232: Replace existing hvac unit with high efficiency model | $682 | $1,180 |
$682
10,656
kWh
|
|
| TOTAL RECOMMENDED | $2,653 | $3,777 |
$2,653
41,444
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs