| Assessment Year | 2020 |
|---|---|
| Principal Product | Cannabis |
| NAICS | 325411: Medicinal and Botanical Manufacturing |
| SIC | 2833: Medicinal Chemicals and Botanical Products |
| Sales Range | $10 M to 50M |
| # of Employees | 20 |
| Plant Area |
435,600
ft2
|
| Annual Production | 19,520
lb
|
| Production Hrs. Annual | 3,500
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $85,320 | 576,711 |
kWh
|
$0.15 |
| Electricity Demand | $21,150 | 4,032 |
kW-mo/yr
|
$5.25 |
| Natural Gas | $36,000 | 4,337 |
MMBtu
|
$8.30 |
| TOTAL YEARLY COSTS | $142,470 | |||
| RECOMMENDED SAVINGS* | $44,916 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $32,016 | $73,500 |
$31,575
210,499
kWh
|
$8,286
-
kW-mo/yr
|
$(-7,844.2)
-
MMBtu
|
|
| 02 | 2.7135: Install occupancy sensors | $1,344 | $270 |
$1,344
8,967
kWh
|
- | - | |
| 03 | 2.2511: Insulate bare equipment | $11,555 | $51,920 | - | - |
$11,555
-
MMBtu
|
|
| TOTAL RECOMMENDED | $44,916 | $125,690 |
$32,919
219,466
kWh
|
$8,286
-
kW-mo/yr
|
$3,711
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs