| Assessment Year | 2018 |
|---|---|
| Principal Product | Bacon |
| NAICS | 311612: Meat Processed from Carcasses |
| SIC | 2013: Sausages and Other Prepared Meat Products |
| Sales Range | $50 M to 100M |
| # of Employees | 143 |
| Plant Area |
46,000
ft2
|
| Annual Production | 32,000,000
units
|
| Production Hrs. Annual | 6,720
hrs
|
| Location (State) | Montana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $220,339 | 2,797,920 |
kWh
|
$0.079 | |
| Electricity Demand | $55,789 | 5,941 |
kW-mo/yr
|
$9.39 | |
| Electricity Fees | $1,152 | - |
|
- | |
| Natural Gas | $56,507 | 14,568 |
MMBtu
|
$3.88 | |
| Waste Disposal Costs | |||||
| Other Liquid (non-haz) | $10,878 | 36,750 |
gal
|
$0.30 | |
| Solid Waste (haz) | $130,754 | 9,480 |
lb
|
$13.79 | |
| TOTAL YEARLY COSTS | $475,418 | ||||
| RECOMMENDED SAVINGS* | $148,922 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $18,168 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,853 | $2,250 |
$1,853
19,555
kWh
|
- | - | - | - | |
| 02 | 2.2521: Isolate steam lines to avoid heating air conditioned areas | $768 | $1,485 |
$175
2,240
kWh
|
- |
$593
-
MMBtu
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,707 | $2,970 |
$1,405
18,016
kWh
|
$302
-
kW-mo/yr
|
- | - | - | |
| 04 | 3.4111: Use closed cycle process to minimize waste water production | $10,878 | $1,225 | - | - | - |
$10,878
-
gal
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,250 | $60 |
$930
11,928
kWh
|
$319
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,713 | $20 |
$1,410
18,077
kWh
|
$303
-
kW-mo/yr
|
- | - | - | |
| 07 | 3.3122: Use filtration, centrifuging to remove contaminants | $130,754 | $100,744 | - | - | - | - |
$130,754
-
lb
|
|
| TOTAL RECOMMENDED | $148,922 | $108,754 |
$5,773
69,816
kWh
|
$924
-
kW-mo/yr
|
$593
-
MMBtu
|
$10,878
-
gal
|
$130,754
-
lb
|
||
| TOTAL IMPLEMENTED | $18,168 | $8,010 |
$5,773
69,816
kWh
|
$924
-
kW-mo/yr
|
$593
-
MMBtu
|
$10,878
-
gal
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs