| Assessment Year | 2017 |
|---|---|
| Principal Product | Beer |
| NAICS | 312120: Breweries |
| SIC | 2082: Malt Beverages |
| Sales Range | $1 M to 5M |
| # of Employees | 22 |
| Plant Area |
91,476
ft2
|
| Annual Production | 341
Tgal
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Idaho |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $41,516 | 947,628 |
kWh
|
$0.044 | |
| Electricity Demand | $15,067 | 2,784 |
kW-mo/yr
|
$5.41 | |
| Electricity Fees | $479 | - |
|
- | |
| Natural Gas | $38,403 | 5,571 |
MMBtu
|
$6.89 | |
| Waste Disposal Costs | |||||
| Water Usage | $3,210 | 996 |
Tgal
|
$3.22 | |
| Gaseous Waste | $40,298 | 163,109 |
lb
|
$0.25 | |
| TOTAL YEARLY COSTS | $138,974 | ||||
| RECOMMENDED SAVINGS* | $14,036 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Other Liquid (non-haz) Savings | Gaseous Waste Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $1,590 | $2,959 | - | - |
$1,590
-
MMBtu
|
- | - | - | |
| 02 | 3.4113: Treat and reuse rinse waters | $870 | $8,674 | - | - | - |
$870
-
Tgal
|
- | - | |
| 03 | 2.9114: Use solar heat to make electricty | $6,781 | $127,800 |
$6,781
154,786
kWh
|
- | - | - | - | - | |
| 04 | 3.5142: Treat and reuse equipment cleaning solutions | $751 | $5,250 | - | - | - |
$196
-
Tgal
|
$555
-
gal
|
- | |
| 05 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $319 | $2,189 |
$319
7,271
kWh
|
- | - | - | - | - | |
| 06 | 4.212: Adopt in-house material generation | $3,137 | $60,000 | - | - | - | - | - |
$3,137
-
lb
|
|
| 07 | 2.7111: Reduce illumination to minimum necessary levels | $236 | $131 |
$165
3,757
kWh
|
$71
-
kW-mo/yr
|
- | - | - | - | |
| 08 | 2.7135: Install occupancy sensors | $212 | $277 |
$212
4,830
kWh
|
- | - | - | - | - | |
| 09 | 2.7492: Use proper thickness of insulation on building envelope | $140 | $160 |
$140
3,149
kWh
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $14,036 | $207,440 |
$7,617
173,793
kWh
|
$71
-
kW-mo/yr
|
$1,590
-
MMBtu
|
$1,066
-
Tgal
|
$555
-
gal
|
$3,137
-
lb
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Other Liquid (non-haz) Savings | Gaseous Waste Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs