Assessment Year | 2016 |
---|---|
Principal Product | Pickled Asparagus and Beans |
NAICS | 311421: Fruit and Vegetable Canning |
SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
24,500
ft2
|
Annual Production | 1,460,000
pieces
|
Production Hrs. Annual | 1,500
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $6,757 | 125,304 |
kWh
|
$0.054 |
Electricity Demand | $5,229 | 772 |
kW-mo/yr
|
$6.77 |
LPG | $37,001 | 1,896 |
MMBtu
|
$19.52 |
TOTAL YEARLY COSTS | $48,987 | |||
RECOMMENDED SAVINGS* | $1,931 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $154 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
---|---|---|---|---|---|---|
01 | 2.2442: Preheat combustion air with waste heat | $1,545 | $6,216 | - |
$1,545
-
MMBtu
|
|
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $154 | $148 |
$154
2,859
kWh
|
- | |
03 | 2.2623: Minimize condenser cooling water temperature | $232 | $850 |
$232
4,298
kWh
|
- | |
TOTAL RECOMMENDED | $1,931 | $7,214 |
$386
7,157
kWh
|
$1,545
-
MMBtu
|
||
TOTAL IMPLEMENTED | $154 | $148 |
$154
2,859
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs