Assessment Year | 2014 |
---|---|
Principal Product | Railroad Equipment |
NAICS | 336510: Railroad Rolling Stock Manufacturing |
SIC | 3743: Railroad Equipment |
Sales Range | $100 M to 500M |
# of Employees | 536 |
Plant Area |
300,000
ft2
|
Annual Production | 55
pieces
|
Production Hrs. Annual | 5,460
hrs
|
Location (State) | Idaho |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $299,553 | 6,543,278 |
kWh
|
$0.046 |
Electricity Demand | $98,857 | 14,437 |
kW-mo/yr
|
$6.85 |
Electricity Fees | $3,642 | - |
|
- |
Natural Gas | $296,026 | 54,996 |
MMBtu
|
$5.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $72,954 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,861 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2515: Use optimum thickness insulation | $17,744 | $26,100 | - | - |
$17,744
-
MMBtu
|
|
02 | 2.7495: Install replacement doors | $4,556 | $17,436 | - | - |
$4,556
-
MMBtu
|
|
03 | 2.1336: Install equipment to utilize waste fuel | $16,582 | $31,134 | - | - |
$16,582
-
MMBtu
|
|
04 | 2.2437: Recover waste heat from equipment | $2,961 | $10,130 | - | - |
$2,961
-
MMBtu
|
|
05 | 2.2414: Use waste heat from hot flue gases to preheat | $10,250 | $11,371 | - | - |
$10,250
-
MMBtu
|
|
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,963 | $937 |
$3,289
71,382
kWh
|
$674
-
kW-mo/yr
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $16,898 | $2,032 |
$12,393
270,712
kWh
|
$4,505
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $72,954 | $99,140 |
$15,682
342,094
kWh
|
$5,179
-
kW-mo/yr
|
$52,093
-
MMBtu
|
||
TOTAL IMPLEMENTED | $20,861 | $2,969 |
$15,682
342,094
kWh
|
$5,179
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs