Assessment Year | 2013 |
---|---|
Principal Product | Cast and Ductile Iron |
NAICS | 331511: Iron Foundries |
SIC | 3321: Gray and Ductile Iron Foundries |
Sales Range | $500 k to 1M |
# of Employees | 10 |
Plant Area |
25,300
ft2
|
Annual Production | 972
ton
|
Production Hrs. Annual | 3,060
hrs
|
Location (State) | Idaho |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $20,549 | 337,040 |
kWh
|
$0.061 |
Electricity Demand | $23,390 | 4,640 |
kW-mo/yr
|
$5.04 |
Other Gas | $12,000 | 357 |
MMBtu
|
$33.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,366 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,668 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $339 | $120 |
$90
1,497
kWh
|
$249
-
kW-mo/yr
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $478 | $15 |
$363
5,957
kWh
|
$115
-
kW-mo/yr
|
- | - | |
03 | 3.1114: Reuse high ferrous metal dust as raw material | $1,699 | $1,382 |
$(-2.2)
(-36)
kWh
|
- |
$1,883
-
lb
|
$(-182.3) | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,850 | $752 |
$1,850
30,322
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $4,366 | $2,269 |
$2,301
37,740
kWh
|
$365
-
kW-mo/yr
|
$1,883
-
lb
|
$(-182.3) | ||
TOTAL IMPLEMENTED | $2,668 | $887 |
$2,303
37,776
kWh
|
$365
-
kW-mo/yr
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs