Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 4.463: Modify facility to avoid excess maintenance costs | $9,360 | $350 | - | - | $9,360 | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,298 | $14,400 |
$3,298
52,640
kWh
|
- | - | |
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,079 | $117 |
$1,079
17,320
kWh
|
- | - | |
04 | 2.7134: Use photocell controls | $427 | $227 |
$427
6,813
kWh
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $475 | $15 |
$327
5,191
kWh
|
$148
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $14,639 | $15,109 |
$5,131
81,964
kWh
|
$148
-
kW-mo/yr
|
$9,360 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs