Assessment Year | 2014 |
---|---|
Principal Product | Ready-mixed concrete |
NAICS | 327320: Ready-Mix Concrete Manufacturing |
SIC | 3273: Ready-Mixed Concrete |
Sales Range | $50 M to 100M |
# of Employees | 15 |
Plant Area |
23,650
ft2
|
Annual Production | 150,000
units
|
Production Hrs. Annual | 2,392
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $96,661 | 1,394,955 |
kWh
|
$0.069 |
Electricity Demand | $21,772 | 3,353 |
kW-mo/yr
|
$6.49 |
Electricity Fees | $1,055 | - |
|
- |
Natural Gas | $73,858 | 10,150 |
MMBtu
|
$7.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,060 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1221: Replace obsolete burners with more efficient ones | $3,951 | $20,000 | - | - |
$3,951
-
MMBtu
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,465 | $7,100 |
$2,481
35,807
kWh
|
$1,162
-
kW-mo/yr
|
- | $(-99.0) | $(-79.0) | |
03 | 2.1213: Direct warmest air to combustion intake | $2,852 | $5,000 |
$(-41.0)
(-587)
kWh
|
$(-39.0)
-
kW-mo/yr
|
$2,932
-
MMBtu
|
- | - | |
04 | 2.4133: Use most efficient type of electric motors | $1,048 | $2,790 |
$541
7,810
kWh
|
$507
-
kW-mo/yr
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $811 | $200 |
$242
3,497
kWh
|
$569
-
kW-mo/yr
|
- | - | - | |
06 | 2.7135: Install occupancy sensors | $608 | $1,500 |
$436
6,293
kWh
|
$172
-
kW-mo/yr
|
- | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $478 | $350 |
$277
3,395
kWh
|
$36
-
kW-mo/yr
|
- | $69 | $96 | |
08 | 2.7134: Use photocell controls | $444 | $435 |
$231
3,338
kWh
|
$163
-
kW-mo/yr
|
- | $29 | $21 | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,206 | $3,300 |
$722
10,418
kWh
|
$339
-
kW-mo/yr
|
- | $112 | $33 | |
10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $197 | $20 |
$134
1,927
kWh
|
$63
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $15,060 | $40,695 |
$5,023
71,898
kWh
|
$2,972
-
kW-mo/yr
|
$6,883
-
MMBtu
|
$111 | $71 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs