Assessment Year | 2012 |
---|---|
Principal Product | Electronic Assemblies |
NAICS | 334418: Printed Circuit Assembly (Electronic Assembly) Manufacturing |
SIC | 3679: Electronic Components, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 36 |
Plant Area |
23,000
ft2
|
Annual Production | 225,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $49,868 | 636,305 |
kWh
|
$0.078 |
Electricity Fees | $16,339 | - |
|
- |
Natural Gas | $5,146 | 606 |
MMBtu
|
$8.49 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,464 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,648 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,816 | $4,065 |
$1,816
23,157
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,415 | $7,299 |
$4,415
56,315
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,286 | $15,356 |
$7,286
92,937
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $2,161 | $1,050 |
$2,161
27,564
kWh
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $82 | $10 |
$82
1,098
kWh
|
- | |
06 | 2.7232: Replace existing hvac unit with high efficiency model | $3,704 | $40,000 |
$3,006
38,343
kWh
|
$698
-
MMBtu
|
|
TOTAL RECOMMENDED | $19,464 | $67,780 |
$18,766
239,414
kWh
|
$698
-
MMBtu
|
||
TOTAL IMPLEMENTED | $17,648 | $63,715 |
$16,950
216,257
kWh
|
$698
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs