| Assessment Year | 2003 |
|---|---|
| Principal Product | Case Cabinets and Component Wood Products |
| NAICS | 337110: Wood Kitchen Cabinet and Countertop Manufacturing |
| SIC | 2499: Wood Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 450 |
| Plant Area |
400,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $286,605 | 9,385,301 |
kWh
|
$0.031 |
| Electricity Demand | $108,944 | 20,848 |
kW-mo/yr
|
$5.23 |
| Natural Gas | $174,554 | 25,908 |
MMBtu
|
$6.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $97,787 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $56,266 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4239: Eliminate or reduce compressed air usage | $34,795 | $2,160 |
$753
24,674
kWh
|
$46,418
-
kW-mo/yr
|
- | - | - | $(-12,376.0) | - | |
| 02 | 2.7231: Use radiant heater for spot heating | $11,608 | $9,000 | - | - |
$11,608
-
MMBtu
|
- | - | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $8,569 | $15,260 |
$6,870
225,163
kWh
|
$1,699
-
kW-mo/yr
|
- | - | - | - | - | |
| 04 | 4.111: Add equipment/ operators to reduce production bottleneck | $5,816 | $6,800 |
$5,816
190,668
kWh
|
- | - | - | - | - | - | |
| 05 | 2.7135: Install occupancy sensors | $3,047 | $2,175 |
$1,222
40,086
kWh
|
$1,825
-
kW-mo/yr
|
- | - | - | - | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,778 | $444 |
$2,225
72,944
kWh
|
$553
-
kW-mo/yr
|
- | - | - | - | - | |
| 07 | 2.1213: Direct warmest air to combustion intake | $1,244 | $2,500 |
$(-359.0)
(-12,413)
kWh
|
- |
$1,332
-
MMBtu
|
- | $172 | $99 | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $185 | $1,080 |
$127
4,149
kWh
|
$58
-
kW-mo/yr
|
- | - | - | - | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $346 | $135 |
$255
8,359
kWh
|
$86
-
kW-mo/yr
|
- | - | $5 | - | - | |
| 10 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $24,450 | $1,000 | - | - | - |
$24,450
-
lb
|
- | - | - | |
| 11 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $3,873 | $640 | - | - | - |
$3,873
-
lb
|
- | - | - | |
| 12 | 3.4151: Minimize water usage | $1,076 | $690 | - | - | - | - | - | - |
$1,076
-
Tgal
|
|
| TOTAL RECOMMENDED | $97,787 | $41,884 |
$16,909
553,630
kWh
|
$50,639
-
kW-mo/yr
|
$12,940
-
MMBtu
|
$28,323
-
lb
|
$177 | $(-12,277.0) |
$1,076
-
Tgal
|
||
| TOTAL IMPLEMENTED | $56,266 | $28,609 |
$17,013
557,684
kWh
|
$50,553
-
kW-mo/yr
|
- | - | - | $(-12,376.0) |
$1,076
-
Tgal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs