Assessment Year | 2002 |
---|---|
Principal Product | Modular Homes |
NAICS |
n/a
|
SIC | 3219: |
Sales Range | $5 M to 10M |
# of Employees | 66 |
Plant Area |
54,000
ft2
|
Annual Production | 250
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $23,275 | 333,853 |
kWh
|
$0.070 |
Electricity Demand | $3,668 | 1,465 |
kW-mo/yr
|
$2.50 |
Natural Gas | $17,155 | 17,050 |
MMBtu
|
$1.01 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,131 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,929 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $3,511 | $8,000 | - | - |
$3,511
-
MMBtu
|
- | - | - | - | |
02 | 2.2437: Recover waste heat from equipment | $1,250 | $1,500 | - | - |
$1,250
-
MMBtu
|
- | - | - | - | |
03 | 2.7134: Use photocell controls | $452 | $1,000 | - |
$370
-
kW-mo/yr
|
- | - | $33 | $49 | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $345 | $700 |
$251
22
kWh
|
$94
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $104 | - |
$76
7
kWh
|
$28
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 3.4151: Minimize water usage | $334 | $200 | - | - | - |
$334
-
Tgal
|
- | - | - | |
07 | 2.8113: Purchase gas directly from a contract gas supplier | $7,522 | $2,000 | - | - | - | - | - | $7,522 | - | |
08 | 4.454: Modify startup/shutdown times | $3,668 | $4,000 | - |
$3,668
-
kW-mo/yr
|
- | - | - | - | - | |
09 | 4.447: Automate payroll system | $2,945 | $2,495 | - | - | - | - | - | - | $2,945 | |
TOTAL RECOMMENDED | $20,131 | $19,895 |
$327
29
kWh
|
$4,160
-
kW-mo/yr
|
$4,761
-
MMBtu
|
$334
-
Tgal
|
$33 | $7,571 | $2,945 | ||
TOTAL IMPLEMENTED | $1,929 | $2,400 |
$251
22
kWh
|
$94
-
kW-mo/yr
|
$1,250
-
MMBtu
|
$334
-
Tgal
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs