| Assessment Year | 1999 |
|---|---|
| Principal Product | Fabricated Rubber Products |
| NAICS |
n/a
|
| SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 45 |
| Plant Area |
32,000
ft2
|
| Annual Production | 700,000
lb
|
| Production Hrs. Annual | 4,290
hrs
|
| Location (State) | not found |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $40,641 | 646,249 |
kWh
|
$0.063 |
| Electricity Demand | $8,133 | 3,456 |
kW-mo/yr
|
$2.35 |
| Electricity Fees | $4,466 | - |
|
- |
| Natural Gas | $4,685 | 1,142 |
MMBtu
|
$4.10 |
| Other Gas | $1,513 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $30,543 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $29,305 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,333 | $2,050 |
$1,227
19,050
kWh
|
$106
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7135: Install occupancy sensors | $325 | $675 |
$290
4,396
kWh
|
$35
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $141 | - |
$128
2,052
kWh
|
$13
-
kW-mo/yr
|
- | - | - | |
| 04 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $25,426 | $5,000 | - | - | - |
$25,426
-
gal
|
- | |
| 05 | 3.4114: Replace city water with recycled water via cooling tower | $1,238 | $3,500 | - | - |
$1,238
-
Tgal
|
- | - | |
| 06 | 4.513: Re-arrange equipment layout to reduce labor costs | $2,080 | $6,500 | - | - | - | - | $2,080 | |
| TOTAL RECOMMENDED | $30,543 | $17,725 |
$1,645
25,498
kWh
|
$154
-
kW-mo/yr
|
$1,238
-
Tgal
|
$25,426
-
gal
|
$2,080 | ||
| TOTAL IMPLEMENTED | $29,305 | $14,225 |
$1,645
25,498
kWh
|
$154
-
kW-mo/yr
|
- |
$25,426
-
gal
|
$2,080 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Other Liquid (haz) Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs