Assessment Year 1999
Principal Product Heat Treating
NAICS
n/a
SIC 3398: Metal Heat Treating
Sales Range $1
M
to 5
M
# of Employees 34
Plant Area 15,823
ft2
Annual Production 3,000,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $90,965 2,234,467
kWh
Electricity Demand $109,392 9,114
kW-mo/yr
Electricity Fees $1,251 -
Natural Gas $2,887 497
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $43,861 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $39,862 $80,000 $27,748
764,361
kWh
$25,200
-
kW-mo/yr
$(-13,086.0)
-
MMBtu
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $1,214 $1,200 $742
20,516
kWh
$472
-
kW-mo/yr
- -
03 2.4133: Use most efficient type of electric motors $1,289 $1,220 $874
24,033
kWh
$415
-
kW-mo/yr
- -
04 2.7135: Install occupancy sensors $949 $375 $458
12,603
kWh
$491
-
kW-mo/yr
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $303 $240 $174
4,689
kWh
$129
-
kW-mo/yr
- -
06 3.4151: Minimize water usage $244 $1,120 - - - $244
-
Tgal
TOTAL RECOMMENDED $43,861 $84,155 $29,996
826,202
kWh
$26,707
-
kW-mo/yr
$(-13,086.0)
-
MMBtu
$244
-
Tgal
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs