Assessment Year | 1999 |
---|---|
Principal Product | Turbine Engine Components |
NAICS |
n/a
|
SIC | 3724: Aircraft Engines and Engine Parts |
Sales Range | $10 M to 50M |
# of Employees | 465 |
Plant Area |
177,600
ft2
|
Annual Production | 3,500,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $371,622 | 9,557,444 |
kWh
|
$0.039 |
Electricity Demand | $231,426 | 19,838 |
kW-mo/yr
|
$11.67 |
Electricity Fees | $13,230 | - |
|
- |
Natural Gas | $31,659 | 6,800 |
MMBtu
|
$4.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $58,010 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,941 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,002 | $27,440 |
$6,977
179,367
kWh
|
$4,025
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7135: Install occupancy sensors | $2,901 | $1,050 |
$1,845
47,479
kWh
|
$1,056
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $2,923 | $8,000 |
$2,252
58,030
kWh
|
$671
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,514 | $4,000 |
$2,913
75,029
kWh
|
$1,008
-
kW-mo/yr
|
$(-1,407.0)
-
MMBtu
|
- | - | - | |
05 | 2.7231: Use radiant heater for spot heating | $1,339 | $1,600 |
$254
6,448
kWh
|
$74
-
kW-mo/yr
|
$1,011
-
MMBtu
|
- | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $707 | $900 |
$385
9,965
kWh
|
$322
-
kW-mo/yr
|
- | - | - | - | |
07 | 3.4111: Use closed cycle process to minimize waste water production | $2,232 | $4,200 | - | - | - |
$2,232
-
Tgal
|
- | - | |
08 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,217 | $7,000 | - | - | - | - |
$2,217
-
lb
|
- | |
09 | 3.4151: Minimize water usage | $1,215 | $3,125 | - | - | - |
$1,215
-
Tgal
|
- | - | |
10 | 4.445: Install equipment to move product | $30,960 | $50,000 | - | - | - | - | - | $30,960 | |
TOTAL RECOMMENDED | $58,010 | $107,315 |
$14,626
376,318
kWh
|
$7,156
-
kW-mo/yr
|
$(-396.0)
-
MMBtu
|
$3,447
-
Tgal
|
$2,217
-
lb
|
$30,960 | ||
TOTAL IMPLEMENTED | $13,941 | $32,540 |
$7,362
189,332
kWh
|
$4,347
-
kW-mo/yr
|
- |
$2,232
-
Tgal
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs