Assessment Year | 1995 |
---|---|
Principal Product | Commercial Offset Prints |
NAICS |
n/a
|
SIC | 2751: |
Sales Range | $5 M to 10M |
# of Employees | 68 |
Plant Area |
29,030
ft2
|
Annual Production | 60,000
lb
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $87,228 | 718,347 |
kWh
|
$0.12 |
Natural Gas | $7,438 | 1,660 |
MMBtu
|
$4.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,818 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,575 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $3,242 | $3,430 |
$3,242
26,671
kWh
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $333 | $20 |
$333
2,638
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $246 | $160 |
$246
2,052
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $997 | $1,531 |
$997
8,206
kWh
|
|
TOTAL RECOMMENDED | $4,818 | $5,141 |
$4,818
39,567
kWh
|
||
TOTAL IMPLEMENTED | $3,575 | $3,450 |
$3,575
29,309
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs