| Assessment Year | 1995 |
|---|---|
| Principal Product | Printed Labels |
| NAICS |
n/a
|
| SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 450 |
| Plant Area |
117,216
ft2
|
| Annual Production | 200,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $427,155 | 8,457,796 |
kWh
|
$0.051 |
| Natural Gas | $156,656 | 44,735 |
MMBtu
|
$3.50 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,009 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,565 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $3,801 | $5,910 |
$3,801
77,667
kWh
|
- | |
| 02 | 2.6218: Turn off equipment when not in use | $286 | $250 |
$286
5,862
kWh
|
- | |
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $6,524 | $20 | - |
$6,524
-
MMBtu
|
|
| 04 | 2.6214: Shut off pilots in standby equipment | $52 | $20 | - |
$52
-
MMBtu
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,119 | $1,064 |
$2,119
43,376
kWh
|
- | |
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $5,041 | $552 |
$5,041
103,165
kWh
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $186 | $285 |
$186
3,810
kWh
|
- | |
| TOTAL RECOMMENDED | $18,009 | $8,101 |
$11,433
233,880
kWh
|
$6,576
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $11,565 | $572 |
$5,041
103,165
kWh
|
$6,524
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs