| Assessment Year | 1995 |
|---|---|
| Principal Product | Slag Pot Carriers, Coal Haulers |
| NAICS |
n/a
|
| SIC | 3531: Construction Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 130 |
| Plant Area |
118,194
ft2
|
| Annual Production | 50
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $119,861 | 1,742,966 |
kWh
|
$0.069 |
| Natural Gas | $32,117 | 14,672 |
MMBtu
|
$2.19 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,628 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,461 | $5,627 | n/a |
$4,461
64,771
kWh
|
- |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $1,222 | $600 | n/a |
$1,222
17,878
kWh
|
- |
| 03 | 2.2437: Recover waste heat from equipment | $1,583 | $3,000 | n/a | - |
$1,583
-
MMBtu
|
| 04 | 2.2531: Re-size charging openings or add movable cover or door | $1,362 | $5,900 | n/a | - |
$1,362
-
MMBtu
|
| TOTAL RECOMMENDED | $8,628 | $15,127 |
$5,683
82,649
kWh
|
$2,945
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs