Assessment Year 1994
Principal Product Air Cannons, Industrial Vibrators and Flow Aid Devices
NAICS
n/a
SIC 3531: Construction Machinery and Equipment
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 145,572
ft2
Annual Production 165,000
pieces
Production Hrs. Annual 7,200
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $176,558 2,407,093
kWh
Natural Gas $6,722 1,613
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $83,012 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $15,755

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $6,475 $22,315 $6,475
88,218
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,194 $4,456 $2,194
29,894
kWh
-
03 2.7135: Install occupancy sensors $1,322 $150 $1,322
18,171
kWh
-
04 2.4133: Use most efficient type of electric motors $1,870 $3,200 $1,870
25,498
kWh
-
05 2.6231: Utilize controls to operate equipment only when needed $3,894 $1,000 $3,894
53,048
kWh
-
06 2.1311: Replace electrically-operated equipment with fossil fuel equipment $41,565 $17,500 $61,285
835,580
kWh
$(-19,720.0)
-
MMBtu
07 2.1311: Replace electrically-operated equipment with fossil fuel equipment $2,035 $6,000 $2,035
27,843
kWh
-
08 2.1311: Replace electrically-operated equipment with fossil fuel equipment $23,657 $62,000 $31,913
435,229
kWh
$(-8,256.0)
-
MMBtu
TOTAL RECOMMENDED $83,012 $116,621 $110,988
1,513,481
kWh
$(-27,976.0)
-
MMBtu
TOTAL IMPLEMENTED $15,755 $31,121 $15,755
214,829
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs