Assessment Year | 1988 |
---|---|
Principal Product | CUSTOM FILTERS |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 0
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $108,552 | 1,774,912 |
kWh
|
$0.061 |
Natural Gas | $33,341 | 6,968 |
MMBtu
|
$4.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,996 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,996 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $13,458 | $30,640 |
$13,458
220,106
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $179 | $366 |
$179
2,931
kWh
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $359 | - |
$359
5,862
kWh
|
|
TOTAL RECOMMENDED | $13,996 | $31,006 |
$13,996
228,899
kWh
|
||
TOTAL IMPLEMENTED | $13,996 | $31,006 |
$13,996
228,899
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs