| Assessment Year | 1988 |
|---|---|
| Principal Product | KNIT SHIRTS |
| NAICS |
n/a
|
| SIC | 2321: Men's and Boys' Shirts, Except Work Shirts |
| Sales Range | $10 M to 50M |
| # of Employees | 300 |
| Plant Area |
n/a
|
| Annual Production | 4,800,000
pieces
|
| Production Hrs. Annual | 2,500
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $65,980 | 1,055,979 |
kWh
|
$0.062 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,762 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,122 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.2522: Isolate hot or cold equipment | $1,869 | - |
$1,869
29,894
kWh
|
|
| 02 | 2.7123: Keep lamps and reflectors clean | $2,253 | $4,245 |
$2,253
36,049
kWh
|
|
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $183 | - |
$183
2,931
kWh
|
|
| 04 | 2.4312: Improve lubrication practices | $457 | - |
$457
7,327
kWh
|
|
| TOTAL RECOMMENDED | $4,762 | $4,245 |
$4,762
76,201
kWh
|
||
| TOTAL IMPLEMENTED | $4,122 | $4,245 |
$4,122
65,943
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs