| Assessment Year | 1987 |
|---|---|
| Principal Product | CHAIRS |
| NAICS |
n/a
|
| SIC | 2521: Wood Office Furniture |
| Sales Range | $10 M to 50M |
| # of Employees | 245 |
| Plant Area |
n/a
|
| Annual Production | 100,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $116,515 | 1,662,954 |
kWh
|
$0.070 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,875 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,106 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $769 | $394 |
$769
10,844
kWh
|
- | |
| 02 | 2.7226: Use computer programs to optimize hvac performance | $2,616 | $6,000 |
$2,616
37,222
kWh
|
- | |
| 03 | 2.5194: Redesign process | $6,403 | - |
$1,403
19,930
kWh
|
$5,000 | |
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $804 | $1,800 |
$804
11,430
kWh
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $480 | $731 |
$480
6,741
kWh
|
- | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,133 | - |
$1,133
16,120
kWh
|
- | |
| 07 | 2.4312: Improve lubrication practices | $670 | - |
$670
9,672
kWh
|
- | |
| TOTAL RECOMMENDED | $12,875 | $8,925 |
$7,875
111,959
kWh
|
$5,000 | ||
| TOTAL IMPLEMENTED | $12,106 | $8,531 |
$7,106
101,115
kWh
|
$5,000 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs