| Assessment Year | 1987 |
|---|---|
| Principal Product | AUTOMOTIVE PARTS |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 1,200,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $81,540 | 1,263,482 |
kWh
|
$0.065 |
| LPG | $65,364 | 7,524 |
MMBtu
|
$8.69 |
| Fuel Oil #2 | $13,373 | 2,600 |
MMBtu
|
$5.14 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,889 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,000 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $17,889 | $30,000 | - |
$17,889
-
MMBtu
|
- | - | |
| 02 | 2.2437: Recover waste heat from equipment | $587 | $1,500 | - |
$587
-
MMBtu
|
- | - | |
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $111 | - | - | - |
$211
-
MMBtu
|
$(-100.0) | |
| 04 | 2.4133: Use most efficient type of electric motors | $97 | $173 |
$97
1,465
kWh
|
- | - | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $205 | - |
$205
3,224
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $18,889 | $31,673 |
$302
4,689
kWh
|
$18,476
-
MMBtu
|
$211
-
MMBtu
|
$(-100.0) | ||
| TOTAL IMPLEMENTED | $1,000 | $1,673 |
$302
4,689
kWh
|
$587
-
MMBtu
|
$211
-
MMBtu
|
$(-100.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs