Assessment Year | 1987 |
---|---|
Principal Product | WOMENS UNDERGARMENTS |
NAICS |
n/a
|
SIC | 2341: Women's, Misses', Children's, and Infants' Underwear and Nightwear |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 2,400,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $70,278 | 1,065,064 |
kWh
|
$0.066 |
Natural Gas | $4,891 | 726 |
MMBtu
|
$6.74 |
Coal | $7,493 | 2,363 |
MMBtu
|
$3.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,249 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,669 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,141 | $481 |
$1,141
17,292
kWh
|
- | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $580 | $1,500 |
$1,025
15,533
kWh
|
$(-445.0)
-
MMBtu
|
|
03 | 2.7226: Use computer programs to optimize hvac performance | $1,199 | $1,000 |
$1,199
18,171
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $174 | $50 |
$174
2,638
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $155 | - |
$155
2,345
kWh
|
- | |
TOTAL RECOMMENDED | $3,249 | $3,031 |
$3,694
55,979
kWh
|
$(-445.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,669 | $1,531 |
$2,669
40,446
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs