| Assessment Year | 1987 |
|---|---|
| Principal Product | PLYWOOD PANELS & CABINET DOORS |
| NAICS |
n/a
|
| SIC | 2435: Hardwood Veneer and Plywood |
| Sales Range | $5 M to 10M |
| # of Employees | 135 |
| Plant Area |
n/a
|
| Annual Production | 5,000
thousand feet
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $108,315 | 1,482,122 |
kWh
|
$0.073 |
| Coal | $13,910 | 6,755 |
MMBtu
|
$2.06 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,062 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,784 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $878 | $1,605 |
$878
12,016
kWh
|
|
| 02 | 2.2128: Use steam condensate for hot water supply (non-potable) | $1,135 | $2,000 |
$1,135
15,533
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $278 | $157 |
$278
3,810
kWh
|
|
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $771 | - |
$771
10,551
kWh
|
|
| TOTAL RECOMMENDED | $3,062 | $3,762 |
$3,062
41,910
kWh
|
||
| TOTAL IMPLEMENTED | $2,784 | $3,605 |
$2,784
38,100
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs