| Assessment Year | 1987 |
|---|---|
| Principal Product | GASKETS & HOSES |
| NAICS |
n/a
|
| SIC | 3053: Gaskets, Packing, and Sealing Devices |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
n/a
|
| Annual Production | 7,700,000
pieces
|
| Production Hrs. Annual | 4,080
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $20,582 | 337,925 |
kWh
|
$0.061 |
| Natural Gas | $5,227 | 834 |
MMBtu
|
$6.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,175 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $410 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $107 | $108 |
$107
1,758
kWh
|
- | |
| 02 | 2.7226: Use computer programs to optimize hvac performance | $303 | $500 |
$303
4,982
kWh
|
- | |
| 03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,391 | $3,000 |
$4,266
70,047
kWh
|
$(-1,875.0)
-
MMBtu
|
|
| 04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $2,374 | $4,200 |
$2,374
38,980
kWh
|
- | |
| TOTAL RECOMMENDED | $5,175 | $7,808 |
$7,050
115,767
kWh
|
$(-1,875.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $410 | $608 |
$410
6,740
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs