Assessment Year | 1986 |
---|---|
Principal Product | WOMENS & CHILDREN'S WEAR |
NAICS |
n/a
|
SIC | 2341: Women's, Misses', Children's, and Infants' Underwear and Nightwear |
Sales Range | $5 M to 10M |
# of Employees | 140 |
Plant Area |
n/a
|
Annual Production | 720,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $57,190 | 662,954 |
kWh
|
$0.086 |
LPG | $5,163 | 575 |
MMBtu
|
$8.98 |
Fuel Oil #1 | $2,721 | 387 |
MMBtu
|
$7.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,519 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,519 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $101 | - |
$101
1,172
kWh
|
|
02 | 2.7226: Use computer programs to optimize hvac performance | $3,994 | $2,000 |
$3,994
46,307
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,424 | $4,759 |
$4,424
51,290
kWh
|
|
TOTAL RECOMMENDED | $8,519 | $6,759 |
$8,519
98,769
kWh
|
||
TOTAL IMPLEMENTED | $8,519 | $6,759 |
$8,519
98,769
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs