| Assessment Year | 1985 |
|---|---|
| Principal Product | FIBERGLASS YACHTS |
| NAICS |
n/a
|
| SIC | 3732: Boat Building and Repairing |
| Sales Range | $10 M to 50M |
| # of Employees | 400 |
| Plant Area |
n/a
|
| Annual Production | 200
pieces
|
| Production Hrs. Annual | 4,750
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $255,799 | 5,485,932 |
kWh
|
$0.047 |
| Natural Gas | $230,252 | 42,787 |
MMBtu
|
$5.38 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $85,908 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $85,908 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $731 | $1,615 |
$731
15,533
kWh
|
- | |
| 02 | 2.7261: Install timers and/or thermostats | $82,865 | $275 | - |
$82,865
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $394 | $148 |
$394
8,499
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,343 | $227 |
$1,343
28,722
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $575 | $900 |
$575
12,309
kWh
|
- | |
| TOTAL RECOMMENDED | $85,908 | $3,165 |
$3,043
65,063
kWh
|
$82,865
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $85,908 | $3,165 |
$3,043
65,063
kWh
|
$82,865
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs