Assessment Year | 1985 |
---|---|
Principal Product | COMMERCIAL PHOTOGRAPHS |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $114,537 | 2,228,312 |
kWh
|
$0.051 |
Natural Gas | $80,472 | 13,346 |
MMBtu
|
$6.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,905 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $119 | $326 |
$119
14,068
kWh
|
- | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,608 | $300 | - |
$1,608
-
MMBtu
|
|
03 | 2.7226: Use computer programs to optimize hvac performance | $6,714 | $7,200 |
$6,714
130,715
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $210 | $166 |
$210
4,103
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,254 | $446 |
$1,254
24,619
kWh
|
- | |
TOTAL RECOMMENDED | $9,905 | $8,438 |
$8,297
173,505
kWh
|
$1,608
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs