| Assessment Year | 2026 |
|---|---|
| Principal Product | Coal |
| NAICS | 212111: Bituminous Coal and Lignite Surface Mining |
| SIC | 1221: Bituminous Coal and Lignite Surface Mining |
| Sales Range | $50 M to 100M |
| # of Employees | 120 |
| Plant Area |
698,267,000
ft2
|
| Annual Production | 1,500,000
ton
|
| Production Hrs. Annual | 4,320
hrs
|
| Location (State) | New Mexico |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $873,160 | 11,701,200 |
kWh
|
$0.075 |
| Electricity Demand | $795,814 | 96,000 |
kW-mo/yr
|
$8.29 |
| Electricity Fees | $215,285 | - |
|
- |
| Natural Gas | $23,660 | 5,620 |
MMBtu
|
$4.21 |
| Other Gas | $1,973 | 1 |
MMBtu
|
$1,973.00 |
| TOTAL YEARLY COSTS | $1,909,892 | |||
| RECOMMENDED SAVINGS* | $475,666 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $398,173 | $3,607,296 |
$398,173
5,337,436
kWh
|
- | |
| 02 | 2.8114: Change rate schedules or other changes in utility service | $59,900 | $797 | - | $59,900 | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,513 | $13,160 |
$7,513
100,710
kWh
|
- | |
| 04 | 2.7132: Install timers on light switches in little used areas | $4,440 | $1,980 |
$4,440
59,503
kWh
|
- | |
| 05 | 2.7144: Install spectral reflectors / delamp | $1,353 | $4,202 |
$755
10,140
kWh
|
$598 | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,214 | $2,092 | - | $1,214 | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,006 | $268 |
$1,006
13,491
kWh
|
- | |
| 08 | 2.7135: Install occupancy sensors | $982 | $4,140 |
$982
13,127
kWh
|
- | |
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $807 | $2,534 |
$807
10,813
kWh
|
- | |
| 10 | 2.7224: Reduce space conditioning during non-working hours | $278 | $93 |
$278
3,720
kWh
|
- | |
| TOTAL RECOMMENDED | $475,666 | $3,636,562 |
$413,954
5,548,940
kWh
|
$61,712 | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs