Assessment Year | 2023 |
---|---|
Principal Product | treated wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | less than $500 k |
# of Employees | 7 |
Plant Area |
325,500
ft2
|
Annual Production | 300,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | New Mexico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $88,487 | 1,229,760 |
kWh
|
$0.072 |
Electricity Demand | $14,255 | 1,296 |
kW-mo/yr
|
$11.00 |
Electricity Fees | $18,064 | - |
|
- |
TOTAL YEARLY COSTS | $120,806 | |||
RECOMMENDED SAVINGS* | $46,282 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $22,226 | $18,665 |
$18,706
259,954
kWh
|
$3,520
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $13,200 | $21,887 |
$10,164
141,250
kWh
|
$3,036
-
kW-mo/yr
|
- | |
03 | 2.7134: Use photocell controls | $8,391 | $6,033 |
$7,060
98,112
kWh
|
$1,331
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,591 | $2,841 |
$1,172
16,293
kWh
|
$243
-
kW-mo/yr
|
$176 | |
05 | 2.7135: Install occupancy sensors | $874 | $1,115 |
$724
10,054
kWh
|
$150
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $46,282 | $50,541 |
$37,826
525,663
kWh
|
$8,280
-
kW-mo/yr
|
$176 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs