ITAC Assessment: AS0531
ITAC logo
ITAC Assessment: AS0531
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product printed products
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2771: Greeting Cards
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area 60,000
ft2
Annual Production 1,800,000
units
Production Hrs. Annual 3,380
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $113,377 1,424,880
kWh
Electricity Demand $24,956 11,560
kW-mo/yr
Electricity Fees $4,264 -
TOTAL YEARLY COSTS $142,597
RECOMMENDED SAVINGS* $46,521 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
01 2.9114: Use solar heat to make electricty $22,170 $407,250 $16,101
202,279
kWh
$6,069
-
kW-mo/yr
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $10,818 $19,743 $9,654
121,284
kWh
$362
-
kW-mo/yr
$802
03 4.611: Begin a practice of predictive / preventative maintenance $10,375 $17,984 $10,375
130,338
kWh
- -
04 2.7132: Install timers on light switches in little used areas $1,802 $1,824 $1,802
22,636
kWh
- -
05 2.7135: Install occupancy sensors $1,057 $1,319 $1,057
13,286
kWh
- -
06 2.7135: Install occupancy sensors $299 $415 $287
3,606
kWh
$12
-
kW-mo/yr
-
TOTAL RECOMMENDED $46,521 $448,535 $39,276
493,429
kWh
$6,443
-
kW-mo/yr
$802
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs