ITAC Assessment: AS0522
ITAC logo
ITAC Assessment: AS0522
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product Skilled Nursing Care
NAICS 623110: Nursing Care Facilities (Skilled Nursing Facilities)
SIC 8051: Skilled Nursing Care Facilities
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 63,000
ft2
Annual Production 1
units
Production Hrs. Annual 8,736
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $124,904 1,167,449
kWh
Electricity Demand $20,511 3,279
kW-mo/yr
Electricity Fees $2,376 -
LPG $27,000 860
MMBtu
TOTAL YEARLY COSTS $174,791
RECOMMENDED SAVINGS* $55,704 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $55,645

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4322: Use or replace with energy efficient substitutes $21,984 $54,180 $16,851
157,487
kWh
$5,133
-
kW-mo/yr
02 2.9114: Use solar heat to make electricty $21,588 $279,240 $19,786
184,915
kWh
$1,802
-
kW-mo/yr
03 4.611: Begin a practice of predictive / preventative maintenance $11,084 $17,430 $11,084
103,589
kWh
-
04 2.6218: Turn off equipment when not in use $516 $200 $492
4,596
kWh
$24
-
kW-mo/yr
05 2.7272: Install heat pipes / raise cooling setpoint $473 $52 $369
3,455
kWh
$104
-
kW-mo/yr
06 2.7134: Use photocell controls $59 $97 $59
548
kWh
-
TOTAL RECOMMENDED $55,704 $351,199 $48,641
454,590
kWh
$7,063
-
kW-mo/yr
TOTAL IMPLEMENTED $55,645 $351,102 $48,582
454,042
kWh
$7,063
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs