Assessment Year | 2021 |
---|---|
Principal Product | Dehydrated Fruits |
NAICS | 311423: Dried and Dehydrated Food Manufacturing |
SIC | 2034: Dried and Dehydrated Fruits, Vegetables, and Soup Mixes |
Sales Range | less than $500 k |
# of Employees | 8 |
Plant Area |
125,000
ft2
|
Annual Production | 25,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $297,615 | 5,492,160 |
kWh
|
$0.054 |
Electricity Demand | $351,953 | 21,427 |
kW-mo/yr
|
$16.43 |
Electricity Fees | $7,203 | - |
|
- |
TOTAL YEARLY COSTS | $656,771 | |||
RECOMMENDED SAVINGS* | $160,549 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8112: Combine utility meters | $83,765 | $2,853 |
$45,123
-
kWh
|
$34,957
-
kW-mo/yr
|
$3,685 | - | |
02 | 2.4323: Use optimum size and capacity equipment | $32,780 | $1,503 |
$20,469
377,676
kWh
|
$12,311
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,228 | $16,466 |
$11,275
208,018
kWh
|
$5,172
-
kW-mo/yr
|
- | $(-219.0) | |
04 | 4.114: Add/modify equipment to improve drying process | $11,446 | $21,173 |
$7,888
145,542
kWh
|
$3,558
-
kW-mo/yr
|
- | - | |
05 | 2.7232: Replace existing hvac unit with high efficiency model | $8,417 | $27,733 |
$4,043
74,591
kWh
|
$4,374
-
kW-mo/yr
|
- | - | |
06 | 2.7135: Install occupancy sensors | $7,913 | $1,399 |
$7,913
146,001
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $160,549 | $71,127 |
$96,711
951,828
kWh
|
$60,372
-
kW-mo/yr
|
$3,685 | $(-219.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs