Assessment Year | 2021 |
---|---|
Principal Product | Dehydrated Fruits |
NAICS | 311423: Dried and Dehydrated Food Manufacturing |
SIC | 2034: Dried and Dehydrated Fruits, Vegetables, and Soup Mixes |
Sales Range | less than $500 k |
# of Employees | 200 |
Plant Area |
45,000
ft2
|
Annual Production | 20,000,000
units
|
Production Hrs. Annual | 3,998
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $207,258 | 2,838,080 |
kWh
|
$0.073 |
Electricity Demand | $67,740 | 6,703 |
kW-mo/yr
|
$10.11 |
Electricity Fees | $9,080 | - |
|
- |
TOTAL YEARLY COSTS | $284,078 | |||
RECOMMENDED SAVINGS* | $262,427 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $182,262 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 3.1162: Use less wasteful packaging | $178,199 | $183,215 | - | - | $178,199 | |
02 | 2.4322: Use or replace with energy efficient substitutes | $67,347 | $326,860 |
$56,614
775,537
kWh
|
$10,733
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,366 | $14,494 |
$5,564
76,208
kWh
|
$1,270
-
kW-mo/yr
|
$(-468.0) | |
04 | 2.8114: Change rate schedules or other changes in utility service | $4,270 | $200 |
$25,713
-
kWh
|
$(-21,443.0)
-
kW-mo/yr
|
- | |
05 | 2.6125: Keep equipment clean | $4,063 | $464 |
$2,658
36,412
kWh
|
$1,405
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $1,149 | $1,295 |
$1,149
15,753
kWh
|
- | - | |
07 | 2.7232: Replace existing hvac unit with high efficiency model | $1,033 | $3,432 |
$868
11,895
kWh
|
$165
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $262,427 | $529,960 |
$92,566
915,805
kWh
|
$(-7,870.0)
-
kW-mo/yr
|
$177,731 | ||
TOTAL IMPLEMENTED | $182,262 | $183,679 |
$2,658
36,412
kWh
|
$1,405
-
kW-mo/yr
|
$178,199 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs