Assessment Year | 2021 |
---|---|
Principal Product | Industrial Valves |
NAICS | 332911: Industrial Valve Manufacturing |
SIC | 3491: Industrial Valves |
Sales Range | $10 M to 50M |
# of Employees | 132 |
Plant Area |
98,000
ft2
|
Annual Production | 1,018,931
units
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $148,845 | 1,200,283 |
kWh
|
$0.12 |
Electricity Demand | $13,695 | 2,232 |
kW-mo/yr
|
$6.14 |
Electricity Fees | $22,609 | - |
|
- |
TOTAL YEARLY COSTS | $185,149 | |||
RECOMMENDED SAVINGS* | $52,809 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $46,935 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $24,067 | $104,184 |
$19,474
157,046
kWh
|
$4,593
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,810 | $9,023 |
$11,867
95,698
kWh
|
$2,024
-
kW-mo/yr
|
- | - | $919 | |
03 | 2.8112: Combine utility meters | $4,314 | $200 |
$62,222
-
kWh
|
$(-47,764.0)
-
kW-mo/yr
|
$(-10,144.0) | - | - | |
04 | 2.7144: Install spectral reflectors / delamp | $3,053 | $678 |
$2,895
23,343
kWh
|
$46
-
kW-mo/yr
|
- | - | $112 | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,227 | $8,870 |
$1,784
14,390
kWh
|
$443
-
kW-mo/yr
|
- | - | - | |
06 | 3.5316: Contract a wood pallet recycling company | $1,560 | $453 | - | - | - | $1,560 | - | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $978 | $315 |
$909
7,334
kWh
|
$69
-
kW-mo/yr
|
- | - | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $926 | $250 |
$746
6,014
kWh
|
$180
-
kW-mo/yr
|
- | - | - | |
09 | 2.7135: Install occupancy sensors | $722 | $569 |
$722
5,830
kWh
|
- | - | - | - | |
10 | 2.4239: Eliminate or reduce compressed air usage | $152 | $287 |
$123
989
kWh
|
$29
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $52,809 | $124,829 |
$100,742
310,644
kWh
|
$(-40,380.0)
-
kW-mo/yr
|
$(-10,144.0) | $1,560 | $1,031 | ||
TOTAL IMPLEMENTED | $46,935 | $124,176 |
$38,520
310,644
kWh
|
$7,384
-
kW-mo/yr
|
- | - | $1,031 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs