Assessment Year 2020
Principal Product Treated Wastewater
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range less than $500
k
# of Employees 11
Plant Area 30,000
ft2
Annual Production 2,000,000
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $632,133 9,156,662
kWh
Electricity Demand $83,560 15,989
kW-mo/yr
Electricity Fees $61,539 -
TOTAL YEARLY COSTS $777,232
RECOMMENDED SAVINGS* $266,363 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $180,477

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
01 2.4323: Use optimum size and capacity equipment $176,974 $3,941 $163,403
2,368,160
kWh
$13,571
-
kW-mo/yr
- -
02 2.8112: Combine utility meters $69,299 $735 $107,959
-
kWh
$(-30,500.0)
-
kW-mo/yr
$(-8,160.0) -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $16,587 $9,520 $15,066
218,353
kWh
$1,521
-
kW-mo/yr
- -
04 2.7135: Install occupancy sensors $1,757 $511 $1,757
25,458
kWh
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $1,511 $2,230 $1,323
19,167
kWh
$136
-
kW-mo/yr
- $52
06 2.7272: Install heat pipes / raise cooling setpoint $235 $38 $180
2,606
kWh
$55
-
kW-mo/yr
- -
TOTAL RECOMMENDED $266,363 $16,975 $289,688
2,633,744
kWh
$(-15,217.0)
-
kW-mo/yr
$(-8,160.0) $52
TOTAL IMPLEMENTED $180,477 $6,720 $166,663
2,415,391
kWh
$13,762
-
kW-mo/yr
- $52
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings