| Assessment Year | 2018 |
|---|---|
| Principal Product | aluminum milling cutting |
| NAICS | 332710: Machine Shops |
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 130 |
| Plant Area |
40,000
ft2
|
| Annual Production | 4,000,000
units
|
| Production Hrs. Annual | 4,264
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $107,314 | 1,343,104 |
kWh
|
$0.080 |
| Electricity Demand | $18,386 | 3,962 |
kW-mo/yr
|
$4.64 |
| Electricity Fees | $11,360 | - |
|
- |
| TOTAL YEARLY COSTS | $137,060 | |||
| RECOMMENDED SAVINGS* | $25,069 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,080 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|
| 01 | 3.5311: Recover and reuse waste material | $11,063 | - | - | - | $11,063 | |
| 02 | 2.7232: Replace existing hvac unit with high efficiency model | $6,390 | $30,436 |
$4,806
60,154
kWh
|
$1,584
-
kW-mo/yr
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,690 | $6,300 |
$4,020
50,315
kWh
|
$670
-
kW-mo/yr
|
- | |
| 04 | 2.7135: Install occupancy sensors | $2,926 | $1,565 |
$2,926
36,628
kWh
|
- | - | |
| TOTAL RECOMMENDED | $25,069 | $38,301 |
$11,752
147,097
kWh
|
$2,254
-
kW-mo/yr
|
$11,063 | ||
| TOTAL IMPLEMENTED | $11,080 | $36,736 |
$8,826
110,469
kWh
|
$2,254
-
kW-mo/yr
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs