| Assessment Year | 2006 |
|---|---|
| Principal Product | Food |
| NAICS | 333241: Food Product Machinery Manufacturing |
| SIC | 3556: Food Products Machinery |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
333,294
ft2
|
| Annual Production | 15,000,000
lb
|
| Production Hrs. Annual | 780
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $117,496 | 1,508,050 |
kWh
|
$0.078 |
| Electricity Demand | $3,148 | 624 |
kW-mo/yr
|
$5.04 |
| Natural Gas | $337,987 | 40,835 |
MMBtu
|
$8.28 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,441 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.9112: Use solar heat to heat water | $1,728 | $8,800 |
$1,728
21,605
kWh
|
- | |
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,413 | $1,500 | - |
$1,413
-
MMBtu
|
|
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $529 | $1,500 | - |
$529
-
MMBtu
|
|
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $401 | $1,500 | - |
$401
-
MMBtu
|
|
| 05 | 2.2414: Use waste heat from hot flue gases to preheat | $370 | $1,000 | - |
$370
-
MMBtu
|
|
| TOTAL RECOMMENDED | $4,441 | $14,300 |
$1,728
21,605
kWh
|
$2,713
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs