| Assessment Year | 2006 |
|---|---|
| Principal Product | Calcium carbonate |
| NAICS | 325220: Artificial and Synthetic Fibers and Filaments Manufacturing |
| SIC | 2879: Pesticides and Agricultural Chemicals, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 30 |
| Plant Area |
130,679
ft2
|
| Annual Production | 218,000
ton
|
| Production Hrs. Annual | 2,530
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $934,227 | 11,505,600 |
kWh
|
$0.081 |
| Natural Gas | $55,260 | 4,762 |
MMBtu
|
$11.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $147,900 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,330 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $136,800 | $2 |
$136,800
1,800,000
kWh
|
- | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $9,545 | $7,500 |
$9,545
125,571
kWh
|
- | |
| 03 | 2.2511: Insulate bare equipment | $3 | $1,077 | - |
$3
-
MMBtu
|
|
| 04 | 2.7145: Install skylights | $782 | $4,400 |
$782
10,296
kWh
|
- | |
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $770 | $1,000 | - |
$770
-
MMBtu
|
|
| TOTAL RECOMMENDED | $147,900 | $13,979 |
$147,127
1,935,867
kWh
|
$773
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $10,330 | $12,977 |
$10,327
135,867
kWh
|
$3
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs