Assessment Year | 2006 |
---|---|
Principal Product | Treated lumber |
NAICS | 321114: Wood Preservation |
SIC | 2491: Wood Preserving |
Sales Range | $10 M to 50M |
# of Employees | 46 |
Plant Area |
1,306,794
ft2
|
Annual Production | 48,000,000
units
|
Production Hrs. Annual | 6,096
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $77,051 | 809,360 |
kWh
|
$0.095 |
Electricity Demand | $16,426 | 10,842 |
kW-mo/yr
|
$1.52 |
Natural Gas | $128,808 | 12,554 |
MMBtu
|
$10.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,930 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2135: Repair and eliminate steam leaks | $6,478 | $800 | - | - |
$6,478
-
MMBtu
|
|
02 | 2.4133: Use most efficient type of electric motors | $4,125 | $44,393 |
$3,774
50,392
kWh
|
$351
-
kW-mo/yr
|
- | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,418 | $1,000 | - | - |
$3,418
-
MMBtu
|
|
04 | 2.2136: Install / repair insulation on steam lines | $2,909 | $2,240 | - | - |
$2,909
-
MMBtu
|
|
TOTAL RECOMMENDED | $16,930 | $48,433 |
$3,774
50,392
kWh
|
$351
-
kW-mo/yr
|
$12,805
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs