Assessment Year | 2006 |
---|---|
Principal Product | Melamine products |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 135 |
Plant Area |
37,000
ft2
|
Annual Production | 19,540
pieces
|
Production Hrs. Annual | 6,048
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $48,760 | 649,508 |
kWh
|
$0.075 |
Electricity Demand | $7,718 | 1,585 |
kW-mo/yr
|
$4.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,273 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,620 | $1,000 |
$2,351
28,710
kWh
|
$269
-
kW-mo/yr
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,482 | $7,500 |
$1,330
16,235
kWh
|
$152
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,171 | $5,000 |
$1,051
12,835
kWh
|
$120
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $5,273 | $13,500 |
$4,732
57,780
kWh
|
$541
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs