Assessment Year | 2006 |
---|---|
Principal Product | Lithographic prints |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
43,000
ft2
|
Annual Production | 3,000,000
pieces
|
Production Hrs. Annual | 6,096
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $191,230 | 2,454,010 |
kWh
|
$0.078 |
Electricity Demand | $28,552 | 5,785 |
kW-mo/yr
|
$4.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $64,453 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,182 | $15,913 |
$19,126
229,257
kWh
|
$2,056
-
kW-mo/yr
|
- | |
02 | 4.425: Eliminate/reduce redundant inspections | $15,053 | - | - | - | $15,053 | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $12,196 | - |
$11,288
152,339
kWh
|
$908
-
kW-mo/yr
|
- | |
04 | 2.4223: Install direct acting units in place of compressed air pressure system in safety system | $6,612 | $550 |
$5,833
74,880
kWh
|
$779
-
kW-mo/yr
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,272 | $1,000 | - |
$4,272
-
kW-mo/yr
|
- | |
06 | 2.4323: Use optimum size and capacity equipment | $3,394 | $1,900 |
$3,001
38,520
kWh
|
$393
-
kW-mo/yr
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,386 | $3,000 |
$1,225
15,731
kWh
|
$161
-
kW-mo/yr
|
- | |
08 | 2.9112: Use solar heat to heat water | $358 | $2,800 |
$358
4,801
kWh
|
- | - | |
TOTAL RECOMMENDED | $64,453 | $25,163 |
$40,831
515,528
kWh
|
$8,569
-
kW-mo/yr
|
$15,053 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs