Assessment Year 2006
Principal Product Lithographic prints
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2752: Commercial Printing, Lithographic
Sales Range $10
M
to 50
M
# of Employees 130
Plant Area 43,000
ft2
Annual Production 3,000,000
pieces
Production Hrs. Annual 6,096
hrs
Location (State) Nevada

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $191,230 2,454,010
kWh
Electricity Demand $28,552 5,785
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $64,453 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $21,182 $15,913 $19,126
229,257
kWh
$2,056
-
kW-mo/yr
-
02 4.425: Eliminate/reduce redundant inspections $15,053 - - - $15,053
03 2.7232: Replace existing hvac unit with high efficiency model $12,196 - $11,288
152,339
kWh
$908
-
kW-mo/yr
-
04 2.4223: Install direct acting units in place of compressed air pressure system in safety system $6,612 $550 $5,833
74,880
kWh
$779
-
kW-mo/yr
-
05 2.4231: Reduce the pressure of compressed air to the minimum required $4,272 $1,000 - $4,272
-
kW-mo/yr
-
06 2.4323: Use optimum size and capacity equipment $3,394 $1,900 $3,001
38,520
kWh
$393
-
kW-mo/yr
-
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,386 $3,000 $1,225
15,731
kWh
$161
-
kW-mo/yr
-
08 2.9112: Use solar heat to heat water $358 $2,800 $358
4,801
kWh
- -
TOTAL RECOMMENDED $64,453 $25,163 $40,831
515,528
kWh
$8,569
-
kW-mo/yr
$15,053
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs