Assessment Year | 2006 |
---|---|
Principal Product | Mobile homes |
NAICS | 321991: Manufactured Home (Mobile Home) Manufacturing |
SIC | 2451: Mobile Homes |
Sales Range | $50 M to 100M |
# of Employees | 333 |
Plant Area |
222,000
ft2
|
Annual Production | 2,204
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $119,269 | 1,300,680 |
kWh
|
$0.092 |
Electricity Demand | $9,156 | 5,486 |
kW-mo/yr
|
$1.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,760 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $56,760 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $21,882 | $1,000 |
$21,101
217,659
kWh
|
$781
-
kW-mo/yr
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $18,423 | $15,000 |
$17,770
183,298
kWh
|
$653
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $16,455 | $15,000 |
$15,935
164,374
kWh
|
$520
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $56,760 | $31,000 |
$54,806
565,331
kWh
|
$1,954
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $56,760 | $31,000 |
$54,806
565,331
kWh
|
$1,954
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs